Automatic and Electric Manual Double Start Aerosol Fire Extinguisher Device For Vehicle Engine Room
1. Product Description.
1).Background.
1. At 5:15p.m.,October 2, 2007, a bus from Wansheng District of Chongqin to central downtown caught on fire. Among the 38 passengers, only 11 escaped alive.
2. At 8:25a.m.,June 5, 2009, a No.9 bus caught on fire near the North Third Ring of Chengdu, Sichuan Province, causing 27 dead and 76 injured.
3. At 12:57p.m.,July 19,2016, a Taiwan tour bus caught on fire on the 2nd road occurred in the major fire car accident.Accidents caused all passengers and drivers 24 people were all dead.
2).Product Advantages.
• The product has gone through extensive market researches and numerous scientific experiments.
• The products allow for multiple startup modes (both manual and auto) and cater to different customer demands.
• Integrating new features such as small size,low weight, simple operation and maintenance of the device.
• The mini series products also inherit features of our low-temp series products, which are highly efficient and secure.
3).Product Features.
• Environmentally Friendly;
• Simple to Install and Non Maintenance;
• No Pressurised Cylinder or Pipe Work;
• Cost Effective;
• Tests and Certification.
4).Product Parameters.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
5).Start Model:(Passive) heat self-startup & Electric Startup).
The Device can be started up by heat detction wire and also can be started by swith button to electric start it. at the same time output feedback signal.
6).Application Scope.
1.Potential fire hazard areas,including:
• power distribution cabinets,
• computer rooms,
• UPS systems,
• cable trenches,
• power stations,
• welding machines,
• small-sized precise instrument cabinets,
• automobiles,
• ships,
• trains and other vehicles.
2.Ability to put out Class A, Class B and Class C fires as well as electrical fire occurrences in industrial and civil sites, including:
• offices
• factory workshops,
• supply warehouses,
• air conditioning facilities,
• cable vestibules,
• cable shafts,
• archives (storerooms),
• underground hydraulic stations,
• and communication stations.
7).Requirements for the Install Environment.
(1)Temperature:-50℃~+90℃;
(2)Humidity:≤95%;
(3)Space:Protected Areas are closed or relatively closed.
8.)Note.
The fire extinguisher is coonected to fire fighting control pannel, it is one contents of the fire fighting system. In one system the most can connected 10 fire extinguishes, each fire extinguisher is series connected. If protection area is more than 10 fire extinguishes, should be divided to more system.
9).Fire-Extinguishing Principles.
After the fire-extinguishing device is activated, fire-extinguishing chemicals will produce fire-extinguishing gases through chemical reaction. And the effective constituents for fire-extinguishing are metallic oxide particles and inert gases. Under the effect of heat, the vaporized metal ions and positive ions in the fire-extinguishing gas will collect and then consume the active groups in the flames in large quantities. Also, the process will decrease the number of combustion radicals, absorb as well as neutralize them in an efficient way, so as to achieve fire extinguishing with chemical inhibition.
The condensed aerosol auto fire-extinguishing device will immediately activate when fire danger occurs.The fire extinguishing gases will be quickly emitted by the device to achieve highly effecient fire-extinguishing,minmizing fire loss.
2. Product Function.
1).Startup:
2).(Passive) heat self-startup.
Using the fire detection harness pre-set in the protected area. Once the temperature on the protected area rise to the startup temperature(175±10℃)of fire detection harness, the harness can start the extinguishing device in a second and release extinguishing gas to put out the fire.
3).Electric start/Feedback wiring harness.
①Wire length:0.4m;
②wire:QB-C-125;
③Plug-in type device wiring harness:AMP 282104-1;
④Terminal description of plug:
1-Fire extinguisher positive(Blue);
2-Fire extinguisher negative(Green);
3-Feedback positive(Blue);
4-Feedback negative(Green).
4).Startup mode:(Passive) heat self-startup.
(Passive)Heat Self-start up:Using the fire detection harness pre-set in the protected area. Once the temperature on the protected area rise to the startup temperature(175±10℃)of fire detection harness, the harness can start the extinguishing device in a second and release extinguishing gas to put out the fire. at the same time output signal
<1>.Standard Length of the fire detection wire:1m.(The extra length should be equipped with bridge wire harness).
<2>.Work temperature:175±10℃。
<3>.Feedback function of wiring harness:
①Wire length:0.4m;
②wire:QB-C-125;
③Plug-in type device wiring harness:AMP 282104-1。
④Terminal description of plug:
1- Feedback:positive(Blue);
2- Feedback: negative(Green).
<4>.Many sets of linkage mode: Formed in series through linkage interface.
3.Product Images.
4.Packaging & Shipping
|
|
|
|
|
|
|
|
|
|
|
|
5.Company Information
PRI-SAFETY specialized in fire fighting products:
Fire extinguisher;Fire Suppression System;Aerosol Fire Extinguisher system;Fire hose reel;Fire hydrant;Fire cabinetFire Hose;Sprinkler system;Fire blanket;Fire alarm;Etc.
We have CE, EN3, EN671, EN1869, UL, etc certificates for most of our products.
We mainly export to Europe, Middle east, Africa, Latin America and so on.
We also supply OEM products, High Quality, Professional Service, Honesty is our business basic rules.
6. FAQ.
1). May I get a sample before placing an order?
---Yes, of course. This is our new product ,hope we have chance to work together to win more market.
2). Are your company PRI-SAFETY a manufacturer or trading company?
---We’re a manufacturer.
3). Can you print our logo and support OEM?
---Yes, no problem. OEM supported.
4). How long does it take to delivery?
---Usually in 30~45 days after received down payment.
5).Payment Trems:
---30% T/T as deposit, 70% balance after finish goods and before shipment.
7. Contact ways.
1). E-mail: fire@pri-safety.com
2). Skype: chinesefirefighting
3). Tel: 0086-571-8580 3669
Thank you for browsing! Welcome your inquiry! Any of your questions will get our prompt attention & reply.